Enterprise hardware · New & pre-owned supply
sales@aster-rackit.com English / Global
ProductsView all products
BrandsView all brands
SolutionsView all solutions
ServicesView all services
Resources
AboutView all about
Request a quote

Server systems

GIGABYTE H262-PC2

HCI Server - 3rd Gen Intel® Xeon® Scalable - 2U 4-Node DP 8-Bay Gen4 NVMe/SATA/SAS

Choose the system revision

Parameters and parts below apply only to the selected revision. Check the equipment label before choosing; other revisions need separate confirmation.

Legacy revision · software updates supported. Confirm the required software release, service arrangements and equipment availability before ordering.

Product specifications

Model details for your requirement.

Manufacturer
GIGABYTE
Model
H262-PC2
Product type
Server systems
Revision
100
Dimensions (WxHxD, mm)
2U 4-Node - Rear access 440 x 87.5 x 840
Motherboard
MH62-HD2
CPU
3rd Generation Intel® Xeon® Scalable Processors Dual processor per node, 10nm technology CPU TDP up to 270W Please leave one PCIe slot empty if using processor with 270W TDP NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Socket
Per Node: 2 x LGA 4189 Total: 8 x LGA 4189 Socket P+
Chipset
Intel® C621A Chipset
Memory
Per node: 16 x DIMM slots Total: 64 x DIMM slots DDR4 memory supported only 8-channel memory architecture RDIMM modules up to 128GB supported LRDIMM modules up to 128GB supported 3DS RDIMM/LRDIMM modules up to 256GB supported 1.2V modules: 3200/2933/2666 MHz
LAN
Per node: 1 x Dedicated management port Total: 4 x Dedicated management ports 1 x CMC port
Video
Integrated in Aspeed® AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200@60Hz 32bpp, DDR4 SDRAM Management chip on CMC board: Integrated in Aspeed® AST2520A2-GP
Storage
Per node: 2 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays, from CPU_1 Total: 8 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays, from CPU_1 SAS card is required for SAS devices support
SAS
Depends on SAS add-on card
RAID
Intel® SATA RAID 0/1
Expansion Slots
Per node: Riser Card CRSH01H: - 1 x PCIe x16 (Gen4 x16) low-profile slot, from CPU_0 Riser Card CRSH01E: - 1 x PCIe x16 (Gen4 x16) low-profile slot, from CPU_0 1 x OCP 3.0 slot with PCIe Gen4 x16 bandwidth, from CPU_0 Total: Riser Card CRSH01H x 4: - 4 x PCIe x16 (Gen4 x16) low-profile slots, from CPU_0 Riser Card CRSH01E x 4: - 4 x PCIe x16 (Gen4 x16) low-profile slots, from CPU_0 4 x OCP 3.0 slots with PCIe Gen4 x16 bandwidth, from CPU_0
Internal I/O
Per node: 1 x COM header 1 x TPM header 1 x VROC connector 1 x BMC SGPIO header 1 x JTAG BMC header 1 x PLD header 1 x Clear CMOS jumper 1 x IPMB connector
Front I/O
Per node: 1 x Power button with LED 1 x ID button with LED 1 x Status LED 1 x Reset button Total: 4 x Power buttons with LED 4 x ID buttons with LED 4 x Status LEDs 4 x Reset buttons *1 x CMC Status LED *1 x CMC Reset button *Only one CMC Status LED and Reset button per system
Rear I/O
Per node: 2 x USB 3.0 1 x VGA 1 x MLAN 1 x ID LED Total: 8 x USB 3.0 4 x VGA 4 x MLAN 4 x ID LEDs *1 x CMC port *Only one CMC port per system
Backplane Board
Speed and bandwidth: PCIe Gen4 x4 or SATA 6Gb/s or SAS 12Gb/s
TPM
1 x TPM header with SPI interface Optional TPM2.0 kit: CTM010
Power supply
Dual 2200W 80 PLUS Platinum redundant power supply AC Input: - 100-127V~/ 14A, 47-63Hz - 200-240V~/ 12.6A, 47-63Hz DC Input: - 240Vdc/ 12.6A DC Output: - Max 1200W/ 100-127V~ + 12.12V/ 95.6A + 12Vsb/ 3.5A - Max 2200W/ 200-240V~ + 12.12V/ 178.1A + 12Vsb/ 3.5A NOTE: The system power supply requires C19 power cord Power cords are not included. Specify suitable cords separately.
System Management
Aspeed® AST2600 management controller AMI MegaRAC SP-X Solution Web interface Dashboard HTML5 KVM Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Sensor Reading History Data FRU Information SEL Log in Linear Storage / Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control Advanced power capping LDAP / AD / RADIUS Support Backup & Restore Configuration Remote BIOS/BMC/CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings
OS Compatibility
Windows Server 2016 Windows Server 2019 Windows Server 2022 Red Hat Enterprise Linux 7.9 or later Red Hat Enterprise Linux 8.2 or later Red Hat Enterprise Linux 9.0) or later SUSE Linux Enterprise Server 12 SP5 or later SUSE Linux Enterprise Server 15 SP2 or later Ubuntu 20.04 LTS or later Ubuntu 22.04 LTS or later VMware ESXi 6.7 Update3 P03 or later VMware ESXi 7.0 Update2 or later VMware ESXi 8.0 or later Citrix Hypervisor 8.2.0 or later
System Fans
8 x 80x80x38mm (16,300rpm)
Operating Properties
Operating temperature: 10°C to 35°C* Operating humidity: 8-80% (non-condensing) Non-operating temperature: -40°C to 60°C Non-operating humidity: 20%-95% (non-condensing)
Weight
Net Weight: 27.2 kg
Packaging Dimensions
1180 x 779 x 300 mm
Packaging Content
1 x H262-PC2 8 x CPU heatsinks 1 x 3-Section Rail kit

Configuration options and limits depend on the exact product and revision. Confirm the proposed combination and the supplied parts before ordering; optional features are not necessarily included.

  • Confirm the supplied revision and complete configuration before ordering. Supported options are not necessarily included.
  • Specifications apply to revision 100. Other revisions require separate confirmation.
  • Interface speeds and advertised limits are theoretical maxima. Actual performance depends on the installed configuration.
  • Confirm the included hardware and accessories for the specific offer.

Replacement parts & service options

Find the right part for H262-PC2.

System revision: 100

Select the GIGABYTE part numbers you need and add quantities to your enquiry. Confirm the exact chassis revision, installed components and kit contents before ordering. These options are not a complete system configuration.

14 of 14 parts shown

GIGABYTE H262-PC2 replacement part numbers and quantities
SelectGIGABYTE P/NPart descriptionQuantity
9MH62HD2NR-00Motherboard
25HB2-A66122-K0R3-Section Rail kit
9CFPH004NR-00Front panel board - CFPH004
9CBPH080NR-00Backplane board - CBPH080
9CRSH01ENR-00Riser card - CRSH01E
9CRSH01HNR-00Riser card - CRSH01H
9CLBH020NR-00LAN board - CLBH020
25EP0-222003-D0SPower Supply
25FD0-R181N0-10ROptional: VROC module (Supported for Intel SSD only)
25CP1-018000-Q0ROptional: C19 power cord 125V/15A (US)
25CP3-01830H-Q0ROptional: C19 power cord 250V/16A (EU)
9CMTP160NR-00Optional: M.2 riser card - CMTP160
6NH262Z65SR-00-100Optional: Ring topology kit
6NH262PC2SR-RMA-A100Optional: RMA packaging

0 part numbers selected

Availability, condition and supplied items will be confirmed in your quotation.

Installation & configuration

Define the complete system, not just the chassis.

Processor and memory
Specify the intended workload, processor quantity, memory capacity and any existing parts to retain. Ask for a compatible processor and DIMM population for the exact system revision.
Storage layout
List the required drive type, capacity and bay arrangement. Confirm carriers, backplanes, RAID or HBA controllers and the complete cable set.
Expansion and cooling
Describe GPU and network requirements. Confirm the required risers, slot access, power connections and cooling provisions for the proposed build.
Rack and site requirements
Share available rack space, rack depth, power input and redundancy requirements. Agree on rails, regional power cords and the installation environment.

Included hardware

Make the offer clear, line by line.

What ships with the model?

Identify processors, DIMMs, drives, carriers, adapters, controllers, fans, power supplies, risers, rails and cables separately. A supported option is not necessarily installed or included.

Ordering and delivery details

Confirm the exact ordering PN, revision, quantity, condition and warranty terms. Agree on packing, destination, lead time and any substitutions before approving the purchase.

Photographs & inspection

Review the actual offered equipment.

Request unit-label photographs, startup information and an installed-component list. Agree on the test scope and records needed for the quoted configuration.

Test workshop and visits

For multi-unit purchases, agree on whether a matched model, revision or configuration is required. Ask for any exceptions to be identified and approved before packing.

Packing and order preparation

Your model enquiry

Questions to settle before purchase.

Is this model name the ordering part number?

Not necessarily. Ask for the complete ordering PN or SKU and the supplied configuration on the quotation. This model page does not assign an unconfirmed sales code.

Can I use this with my existing equipment?

Provide the exact installed model, revision, firmware and relevant component labels. Compatibility must be confirmed for that combination rather than inferred from a matching brand or connector.

Are the listed limits available together?

Not necessarily. Maximum memory, expansion, storage and power specifications may have different configuration requirements. Ask for review of the complete proposed build.

Does preparing an enquiry send it to sales?

No. The enquiry page prepares a draft on your device. Review it and share it with your sales contact or use the Contact Us page.

More from this manufacturer

Other GIGABYTE models to compare.

These are separate products, not automatic replacements or compatible accessories.

GIGABYTEServer systems

E165-Z30-AG1

Edge Server - AMD EPYC™ 9006 SP8 Server Processors - 1U UP 4-Bay Gen5 NVMe/SATA/SAS-4

Announced model · availability to be confirmed

Specifications & enquiries
GIGABYTEServer systems

R165-ZG1-CS1

Rack Server - AMD EPYC™ 9006 SP8 Server Processors - 1U UP 1 x PCIe Gen6 GPU Closed-Loop DLC

Announced model · availability to be confirmed

Specifications & enquiries
PHOTOGRAPHS THAT SUPPORT YOUR RFQ

Specify the supplied chassis, not just the model name.

Attach a photo brief to the request for GIGABYTE H262-PC2. This is a checklist to agree, not a record that inspection has already been performed.

01

Front and storage layout

Request a straight-on view with the bezel removed when appropriate. Record the populated bays, blanking panels and drive carriers against the offered chassis configuration.

02

Rear and included options

Ask for both PSU labels, risers, network adapters and the rail kit. Confirm which visible parts are included in the offer rather than assuming the catalog picture defines the BOM.

03

Separate diagnostic evidence

Use an order-specific report for installed CPUs, DIMMs, storage and management access. A blurred background screen in an illustration is not a diagnostic result.

Discuss your requirements

Discuss GIGABYTE H262-PC2.

Add quantity, desired configuration, condition and destination to a model-specific enquiry. Confirm the ordering code and final equipment list with your sales contact.

Prepare this model enquiry